General Guidelines and Specifications for an Evaluated AAC Plastering System

 

 

1.0          General Guidelines for Mineral Type finishes

 

1.1               Compressive strength: As a rule of thumb, compressive strength should not exceed two times the compressive strength of AAC (<1000 psi). This requirement is necessary as system to reduce the differential movement between the coating and the substrate and cracking of the plaster. (Ext./Int.)

 

1.2               Modulus of Elasticity – Low value similar to AAC’s MOE is required to reduce stresses due to movement in the wall / floor systems. (Ext./Int.)

 

1.3               Aesthetic features – Like other finishing system, aesthetic and texture features are typically required / available for AACl approved exterior and interior systems. (Mainly Ext.)

 

1.4               Cost of system – an essential benefit for the complete AAC wall system. The exterior finish is designed to be applied as a one-coat system (3/8” – 7/16”) compared to multi-layers system stucco or EIFS. (Ext./Int. @ 3/16” – 1/4” depending on wall type)

 

1.5               Workability – Most approved exterior and interior plastering systems possess features such as light-weight, relatively low waste during application, excellent coverage per unit weight, and other workability enhancing additives. (Ext./Int.)

 

1.6               Durability – Most approved finishing systems are designed to have higher crack resistance and excellent bonding to AAC. (Ext./Int.)

 

1.7               Excellent resistance to moisture penetration. (Ext.)

 

1.8               Breathable Systems – Like all mineral-based coatings, vapor diffusion is higher than acrylic products. Hence, no condensation or moisture damages in the wall system. (Ext./Int.)

 

1.9               Required Specification / Documents

 

Property

Test Procedure

Compressive Strength

ASTM C109

Density

ASTM C188

Modulus of Elasticity

ASTM C580 (ACI 523.3R Formula)

Water Retention

ASTM C91

Vapor permeability

ASTM E96

Water Penetration

ASTM E514 or

ASTM C413

Application sheet

Required

Product description

Required

Material Cost

Required

 

2.0           General Guidelines for Acrylic Coating / Paint

 

2.1               Aesthetic features – Like other finishing system, aesthetic and texture features are typically required / available for AACl approved exterior and interior systems.

 

2.2               Cost of system – an essential benefit for the complete AAC wall system.

 

2.3               Workability – Most approved exterior and interior plastering systems possess features such as relatively low waste during application and coverage

 

2.4               Durability

 

2.5               Excellent resistance to moisture penetration.

 

2.6               Breathable Systems with high vapor permeability

 

2.7               Required Specification / Documents

 

 

Property

Test Procedure

Vapor permeability

ASTM E96 (Min. 5)

Water Penetration

ASTM D1735

ASTM E331

Or equivalent with pass / fail criteria and quantified flow rate

Bonding and flexibility Properties

Required (psi)

Application sheet

Required

Product description

Required

Material Cost

Required

  SafeCrete provides a full line of mineral-based (Olde World) and acrylic stucco.

Error Occurred While Processing Request

Error Occurred While Processing Request

Error Diagnostic Information

ODBC Error Code = 08001 (Unable to connect to data source)

[Microsoft][ODBC SQL Server Driver][DBNETLIB]SQL Server does not exist or access denied.

The error occurred while processing an element with a general identifier of (CFQUERY), occupying document position (581:1) to (581:96).

Date/Time: 05/18/12 04:14:20
Browser: CCBot/1.0 (+http://www.commoncrawl.org/bot.html)
Remote Address: 38.107.179.220