Testing
and Approvals for AAC Products
![]()
AAC Products have undergone extensive testing and research to establish production and construction standards. The AACPA Technical Committee is extremely active in pursuing code approvals. Below is a list of some of the testing and alpprovals for AAC products. For instruction on the use of particular AAC products, please consult the manufacturer.
|
TEST / Report / Publication |
Description of procedure / project |
|
ASTM C1386 |
Standard Specification for PAAC Wall construction units (test determines the compressive strength of AAC blocks) |
|
ASTM E519 |
Diagonal Shear Testing of AAC Masonry Walls |
|
PA201 DADE COUNTY - LARGE MISSLE TEST |
AAC2.5/32(G-2) Missile Impact Performance |
|
PA202 DADE COUNTY - Criteria for Testing Building Envelope Component Using Uniform Static Air Pressure |
AAC2.5/32(G-2) |
|
ASTM C 185 |
Test Method for Air Content of Hydraulic-Cement |
|
ASTM C 91 |
Std Spec for Masonry Cement |
|
ASTM C266 |
Test method for time of setting of Hydraulic-Cement Paste. |
|
ASTM C 1072-94 |
Masonry Flexural Bond Strength |
|
ASTM C 1148 |
Standard Test Method for Measuring the Drying Shrinkage of Masonry Mortar. |
|
ASTM C 1012 |
Standard Test Method for Hydraulic-Cement Exposed to a sulfate solution. |
|
ASTM C67 |
Freeze Thaw Testing |
|
ASTM E330 |
"Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference. |
|
ASTM E331 |
Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. Only one wall assembly with and without finishes. |
|
ASTM E72 |
Methods of Construction Strength Tests of Panels for Building Construction Section 14: Racking Load - Evaluation of Sheathing Materials on a Standard Wood Frame |
|
ASTM C1262 |
Freeze Thaw Testing |
|
ASTM E96 |
Water Vapor Transmission |
|
AATCC/ICBO 127-1995 |
Water Penetration/Flow Rate |
|
UL263 (ASTM E119) |
Fire classification for AAC 2" PowerPanel |
|
UL263 (ASTM E119) |
Fire classification for various AAC wall and floor systems |
|
NER Report 588 |
Structural and Thermal |
|
Oak Ridge National Laboratory Thermal Performance Report |
Thermal Evaluation of AAC2.5/32 including thermal mass benefit in residential construction in six major cities |
|
ASTM C518 |
Thermal Conductivity Test |
|
ASTM C1386 |
Standard Specifications for AAC Wall Units |
| ASTM C1452 | Standard Specification for Reinforced Autoclaved Aerated Concrete Elements |
|
NER 531 |
Structural, Fire, Thermal and Sound Isolation for all AAC product lines |
|
ASTM C 270 |
"Standard Test Method for Compressive Strength of Hydraulic Cement Mortars" |
|
ASTM C 270 |
"Standard Specifications for Mortar for Unit Masonry Standard Specification for Masonry Cement" |
|
ASTM E 136 |
Standard Test Method for Behavior of material in a Vertical Tube Furnace "Combustibility Test" |
|
ASTM E 119 |
"Standard Test Methods for Fire Tests of Building Construction and Materials" |
|
ASTM E 90 & ASTM C 423 |
Standard Method for Laboratory Measurement of Airborne Sound Transmission Loss of building Partitions" & " Test method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room method" |
|
Various Thermal and research and studies for code compliance and load calculation |
|
| K908 | 8 INCH FLOOR PANELS |
| K909 | 4-10 INCH FLOOR PANELS- Nominal 4 inch thick slab can be used only for 1 hr restrained and unrestrained ratings. Panels to have a minimum 3 in. bearing. |
| K910 | 8 INCH FLOOR PANELS |
| P931 | 8 INCH FLOOR PANELS WITH SPECIFIC CROSS SECTION |
| P932 | 4 -10 INCH FLOOR PANELS WITH SPECIFIC CROSS SECTION |
| P933 | 8 INCH FLOOR PANELS WITH SPECIFIC CROSS SECTION |
| U205 | MATRIX PAAC, min 2 in. thick and max. 2-ft wide panel fastened to the steel studs on both sides of the studs with type S3 hex head type self-drilling, self-tapping screws. Min. 2 fasteners per panel at each stud. |
| U206 | MATRIX PAAC, min. 2 in. thick and max 2 ft wide panel installed between a). Min. 6 AAC blocks, min. 8" AAC wall panel or concrete blocks or b). Any 1hr or 2hr rated stud wall assembly constructed of material and manner described in the individual U300 or U400 series Wall or Partition Design in the UL Fire Resistance Directory. Refer to UL Directory for additional detail. |
| U207 | EXTERIOR CLADDING AND OTHER WALL ASSEMBLY. REFER TO UL DIRECTORY FOR ADDITIONAL DETAIL. |
| U208 | POWERPANEL ASSEMBLY WITH STEEL OR WOOD STUDS. TYPICALLY SPECIFIED FOR PARTY WALL CONSTRUCTION. REFER TO UL DIRECTORY. FIRE RATING DEPENDS ON THICKNESS. 2 HR FOR 2" THICKNESS; 3 HR FOR 3" THICKNESS; 4 HR FOR 4" THICKNESS |
| U358 | MIN.
3 INCH PANELS WITH SPECIFIC CROSS SECTION |
| U916 | 8 INCH BLOCK |
| U917 | 6 INCH BLOCK |
| U918 | 8 IN WALL PANEL |
| U919 | 4 INCH BLOCK |
| U920 | 6 IN WALL PANEL |
| U921 | 6 INCH BLOCK |
| U925 | 4 INCH BLOCK ASSEMBLY WITH STEEL OR WOOD STUDS |
| V420 | MIN. 3 INCH PANELS WITH SPECIFIC CROSS SECTION |
| X901 | Min. 4 IN BLOCK OR MIN. 8 IN PANEL INSTALLED HORIZONTALLY OR VERTICALLY. PANELS ATTACHED TO THE CONCRETE FLOOR AND CEILING. |
| C-BJ-1037 | FLOOR, ROOF/CEILING ASSEMBLY; THROUGH PENETRATION FIRE STOP SYSTEM FOR SINGLE PENETRATION |
| C-BJ-8010 | FLOOR, ROOF/CEILING ASSEMBLY; THROUGH PENETRATION FIRE STOP SYSTEM FOR MULTIPLE PENETRATIONS |
| W-J-8009 | WALL ASSEMBLY THROUGH PENETRATION FIRE STOP SYSTEM FOR MULTIPLE PENETRATIONS |
NER International Evaluation Reports