Testing and Approvals for AAC Products

AAC Products have undergone extensive testing and research to establish production and construction standards. The AACPA Technical Committee is extremely active in pursuing code approvals. Below is a list of some of the testing and alpprovals for AAC products. For instruction on the use of particular AAC products, please consult the manufacturer.

TEST / Report / Publication

Description of procedure / project

ASTM C1386

Standard Specification for PAAC Wall construction units (test determines the compressive strength of AAC blocks)

ASTM E519

Diagonal Shear Testing of AAC Masonry Walls

PA201 DADE COUNTY - LARGE MISSLE TEST

AAC2.5/32(G-2) Missile Impact Performance

PA202 DADE COUNTY - Criteria for Testing Building Envelope Component Using Uniform Static Air Pressure

AAC2.5/32(G-2)

ASTM C 185

Test Method for Air Content of Hydraulic-Cement

ASTM C 91

Std Spec for Masonry Cement

ASTM C266

Test method for time of setting of Hydraulic-Cement Paste.

ASTM C 1072-94

Masonry Flexural Bond Strength

ASTM C 1148

Standard Test Method for Measuring the Drying Shrinkage of Masonry Mortar.

ASTM C 1012

Standard Test Method for Hydraulic-Cement Exposed to a sulfate solution.

ASTM C67

Freeze Thaw Testing

ASTM E330

"Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference.

ASTM E331

Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.  Only one wall assembly with and without finishes.

ASTM E72

Methods of Construction Strength Tests of Panels for Building Construction Section 14: Racking Load - Evaluation of Sheathing Materials on a Standard Wood Frame

ASTM C1262

Freeze Thaw Testing

ASTM E96

Water Vapor Transmission

AATCC/ICBO 127-1995

Water Penetration/Flow Rate

UL263 (ASTM E119)

Fire classification for AAC 2" PowerPanel

UL263 (ASTM E119)

Fire classification for various AAC wall and floor systems

NER Report 588

Structural and Thermal

Oak Ridge National Laboratory Thermal Performance Report

Thermal Evaluation of AAC2.5/32 including thermal mass benefit in residential construction in six major cities

ASTM C518

Thermal Conductivity Test

ASTM C1386

Standard Specifications for AAC Wall Units

ASTM C1452 Standard Specification for Reinforced Autoclaved Aerated Concrete Elements

NER 531

Structural, Fire, Thermal and Sound Isolation for all AAC product lines

ASTM C 270

"Standard Test Method for Compressive Strength of Hydraulic Cement Mortars"

ASTM C 270

"Standard Specifications for Mortar for Unit Masonry Standard Specification for Masonry Cement"

ASTM E 136

Standard Test Method for Behavior of material in a Vertical Tube Furnace "Combustibility Test"

ASTM E 119

"Standard Test Methods for Fire Tests of Building Construction and Materials"

ASTM E 90 & ASTM C 423

Standard Method for Laboratory Measurement of Airborne Sound Transmission Loss of building Partitions" & " Test method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room method"

Various Thermal and research and studies for code compliance and load calculation

K908 8 INCH FLOOR PANELS
K909 4-10 INCH FLOOR PANELS- Nominal 4 inch thick slab can be used only for 1 hr restrained and unrestrained ratings. Panels to have a minimum 3 in. bearing.
K910 8 INCH FLOOR PANELS
P931 8 INCH FLOOR PANELS WITH SPECIFIC CROSS SECTION
P932 4 -10 INCH FLOOR PANELS WITH SPECIFIC CROSS SECTION
P933 8 INCH FLOOR PANELS WITH SPECIFIC CROSS SECTION
U205 MATRIX PAAC, min 2 in. thick and max. 2-ft wide panel fastened to the steel studs on both sides of the studs with type S3 hex head type self-drilling, self-tapping screws. Min. 2 fasteners per panel at each stud.
U206 MATRIX PAAC, min. 2 in. thick and max 2 ft wide panel installed between a). Min. 6 AAC blocks, min. 8" AAC wall panel or concrete blocks or b). Any 1hr or 2hr rated stud wall assembly constructed of material and manner described in the individual U300 or U400 series Wall or Partition Design in the UL Fire Resistance Directory. Refer to UL Directory for additional detail.
U207 EXTERIOR CLADDING AND OTHER WALL ASSEMBLY. REFER TO UL DIRECTORY FOR ADDITIONAL DETAIL.
U208 POWERPANEL ASSEMBLY WITH STEEL OR WOOD STUDS. TYPICALLY SPECIFIED FOR PARTY WALL CONSTRUCTION. REFER TO UL DIRECTORY. FIRE RATING DEPENDS ON THICKNESS. 2 HR FOR 2" THICKNESS; 3 HR FOR 3" THICKNESS; 4 HR FOR 4" THICKNESS
U358 MIN. 3 INCH PANELS WITH SPECIFIC CROSS SECTION
U916 8 INCH BLOCK
U917 6 INCH BLOCK
U918 8 IN WALL PANEL
U919 4 INCH BLOCK
U920 6 IN WALL PANEL
U921 6 INCH BLOCK
U925 4 INCH BLOCK ASSEMBLY WITH STEEL OR WOOD STUDS
V420
MIN. 3 INCH PANELS WITH SPECIFIC CROSS SECTION
X901 Min. 4 IN BLOCK OR MIN. 8 IN PANEL INSTALLED HORIZONTALLY OR VERTICALLY. PANELS ATTACHED TO THE CONCRETE FLOOR AND CEILING.
C-BJ-1037 FLOOR, ROOF/CEILING ASSEMBLY; THROUGH PENETRATION FIRE STOP SYSTEM FOR SINGLE PENETRATION
C-BJ-8010 FLOOR, ROOF/CEILING ASSEMBLY; THROUGH PENETRATION FIRE STOP SYSTEM FOR MULTIPLE PENETRATIONS
W-J-8009 WALL ASSEMBLY THROUGH PENETRATION FIRE STOP SYSTEM FOR MULTIPLE PENETRATIONS

NER International Evaluation Reports       ASTM website       Underwriters Laboratories, Inc. (UL)